Cookie Consent by Free Privacy Policy website

Bending beam load cell GS-2


Download PDF

Bending beam load cells for weighing platforms, hoppers, tanks, etc. of low and medium capacity

Bending beam load cell

C3 and C4 OIML Homologated from 40 kg to 200 kg


Zoom Click to enlarge image

Bending beam load cell GS-2 Bending beam load cell GS-2 Schema
Analog Output ATEX OIML

Technical Specifications

MaterialStainless steel
Nominal load5, 10, 15, 25, 50, 100, 150, 200, 250, 300, 500 kg
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,03 % F.S.
Hysteresis0,03 % F.S.
Reapeatability0,03 % F.S.
Input resistance380-386 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 MOhm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4° / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 67
Standard cable length5 m – 6 x 0,30 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeSHIELDED CABLE 6C R6 PVC 6X0,30
Length5 m (body lead cell not connected shield)
Red+ IN
Black- IN
Yellow+ REF
Blue- REF
Green+ OUT
White- OUT
Connections  Bending beam load cell GS-2

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means