Cookie Consent by Free Privacy Policy website

Transmitter RQAN


Download PDF

Weight Transmitters with direct connection of one ore more load cells and a wide range of outputs for an easy integration in every industrial and automation system. Comfortable and immediate installation on DIN bar and/or OMEGA bar.

Digital / Analog load cell amplifier

Download installation and usage manual


Manual for serial numbers 2023-0186 or older

Download installation and usage manual


Zoom Click to enlarge image

Transmitter RQAN Transmitter RQAN Schema

Technical Specifications

Power supply24 V direct current ± 10 %
Max power consumption1 Watt
LedThree LED with 3 mm
Overall dimensions110 x 120 x 23 mm
MountingSupport DIN or OMEGA rail
Load cell input featuresMaximum 4 load cells with 350 Ω in parallel (or 8 cells with 700 Ω)
Power supply load cells4 Volt DC
Conforms to standardsEN61000-6-2, EN61000-6-3, EN61010-1
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means