LOAD LIMITER
Limitation of the detected load through alarm and pre-alarm levels.
Overload control with double-security system by connecting two units.
Limitation of load (single and sum) for weighing systems up to 4 points, by connecting more units.
Load cell fail alarm.
Set-up and calibration via keyboard and display board removable.
Click to enlarge image
Power supply | 12 – 24 V ac ± 15 % | |
Average consumption | 4 W | |
Isolation | Class III | |
Operating temperature | -10 / +50 °C (14 / 122 °F) Humidity Maximum 85% non-condensing | |
Storage temperature | -20 / +60°C (-4 / +140°F) | |
Display | Numeric 6-digit, 7-segment LED (h 14mm) | |
Led | 5 3 mm indicator LEDs of which 3 indicate the relay outputs status | |
Keyboard | 4 mechanical keys | |
Overall dimensions | 115 mm x 93 mm x 65 mm / 4.53 x 3.66 x 2.56 in (l x h x p) | |
Mounting | Support for DIN rail or OMEGA bar | |
Case material | Polyamide 6.6 UL 94V-0, self-extinguishing | |
Connections | Removable screw terminals. Pitch screws terminal blocks 5.08 mm | |
Load cell input features | Max 4 | |
Input sensitivity | 0.02 µV min | |
Linearity | < 0.01% full scale | |
Temperature deviation | < 0.001% full scale / C° | |
Internal resolution | 24 bit | |
Measuring range | -3.9 mV/V - +3.9 mV/V | |
Digital filter | from 0.1 Hz to 10 Hz selectable | |
Output rate | 10 Hz | |
Number of weight decimals | from 0 to 3 decimal digit | |
Zero / FS Calibration | Executable through buttons | |
Cell cable interruption check | Always present | |
Analog output in tension | Optional: ± 10 V / ± 5 V | |
Resolution | 16 bits | |
Calibration | By push-buttons | |
Impedance | ≥ 10 kΩ | |
Linearity | 0.03% full scale | |
Temperature deviation | 0.001% full scale / °C | |
Analog output under current | Optional: 0 - 20 mA / 4 - 20 mA | |
Resolution | 16 bits | |
Calibration | By push-buttons | |
Impedance | ≤ 300 Ω | |
Linearity | 0.03% full scale | |
Temperature deviation | 0.001% full scale / °C | |
Logical input | 1 optically isolated dry contact | |
Logical output alarm | 2 relay out (24 V DC/AC, one NO contact), 1 relay out (24 V DC/AC, one changeover contact), relay contact capacity 0.5 A | |
Serial port | Rs232 / Rs485 (alternatively) | |
Max. cable length | 15m (Rs232) and 1000m (Rs485) | |
Baud rate | Up to 115 kb/s (default 9600 b/s) | |
Program code memory | 32 Kbytes | |
Data memory | 2 Kbytes | |
Conforms to standards | Compliance to EMC norms: EN61000-6-2, EN61000-6-3, Compliance electric safety: EN 61010-1 |
Type | 6 Pin pull-out terminal block |
Length | ND |
1 | - Exc. Load cell |
2 | + Exc. Load cell |
3 | + Load cell Sense |
4 | - Load cell Sense |
5 | - Signal load cell |
6 | + signal load cell |
Type | 18 Pin pull-out terminal block |
Length | ND |
7 | RS232 Tx |
8 | RS232 Rx |
9 | RS232 GND |
10 | RS485 + |
11 | RS485 - |
12 | Input (Dry contact) |
13 | Input (Dry contact) |
14 | + ~ (Power supply 12 to 24 Vdc/Vac +/- 15%) |
15 | - ~ (Power supply 12 to 24 Vdc/Vac +/- 15%) |
16 | Analog output + (V or mA) |
17 | Analog output - |
18 | Common Relay Output 1 |
19 | N.O. contact Relay Output 1 |
20 | Common Relay Output 2 |
21 | N.O. contact Relay Output 2 |
22 | Common Relay Output 3 |
23 | N.O. contact Relay Output 3 |
24 | N.C. contact Relay Output 3 |
General precautions to be followed in the installation and assembly of load cells: