Cookie Consent by Free Privacy Policy website

Indicator WIN11


Download PDF

Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.

Indicator

Download installation manual

Download usage manual

Download installation and usage manual


Zoom Click to enlarge image

Indicator WIN11

Technical Specifications

Power supply230 / 115 V ac, 50 / 60 Hz – option 24 V dc
Max power consumption7 W
IsolationClass II
Installation CategoryCategory II
Operating temperature-10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayNumeric 6-digit, 7-segment LED (h 14 mm)
Led8 5 mm indicator LEDs
Keyboard5 mechanical keys
Drilling template139 mm X 67 mm (5.47 x 2.64 in)
Built-in depth5.31 in (including terminal blocks)
Overall dimensions144 x 72 x 120 mm / 5.67 x 2.83 x 4.72 in (l x h x p) (DIN43700)
MountingPanel mount
Case materialSelfextinguish Noryl (UL 94 V1)
Protection levelIP 54
ConnectionsPull-out terminal blocks, pitch 5.08 mm (Power supply pitch 7.5 mm) Serial ports on a 9 pin Sub-D
Power supply load cells5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit
Input sensitivity≥ 0,02 μV
Linearity< 0.01% of full scale
Temperature deviation<0,0003% of full scale/°C
Internal resolution24 bit
Weight resolutionUp to 99.999 divisions
Measuring range-3.9 mV/V - +3.9 mV/V
Digital filter0.2 Hz – 50 Hz, selectable
Output rateFrom 5 to 50 Hz
Number of weight decimalsfrom 0 to 4 decimal digit
Zero / FS CalibrationAutomatic (theoretical) or executable through buttons
Analog output in tensionOptional: 0 – 10 V / 0 – 5 V
 Resolution16 bits
 CalibrationDigital through keyboard
 Impedance≥ 10 kΩ
 Linearity0.03% full scale
 Temperature deviation0.001% full scale/°C
Analog output under currentOptional: 0 - 20 mA / 4 - 20 mA
 Resolution16 bits
 CalibrationDigital through keyboard
 Impedance≤ 300 Ω
 Linearity0.03% full scale
 Temperature deviation0.001% full scale / °C
Analog inputConnection to contraves or selector (as an alternative to the third input)
 Resolution10 bits
Logical output4 relays (NO contact) maximum 115 V ac / 30 V dc, 0.5 A each
Logical input3 opto-isolated at 12 / 24 V dc PNP
Additional logic outputs2 external boards of 8 relays (NO contact) max. 115 V ac / 30 V dc, 0.5 A each.
Serial portCOM1: Rs232c half duplex COM2: Rs422/Rs485 half duplex
 Max. cable length15m (Rs232c) and 1000m (Rs422 and Rs485)
 Serial protocolsASCII, Printers ,Modbus, aquisition from TRF and WST
 Baud rate1200, 2400, 4800, 9600, 19200, 38400, 115000 selectable
Program code memory60 Kbytes FLASH re-programmable on board via RS232
Data memory4 Kbytes
Conforms to standardsEN61000-6-2, EN61000-6-3, EN61010-1, EN45501
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeTerminal block 2P (pitch 7.5)
LengthND
1230V~ Line
2230V~ Neutral
TypeTerminal block 17P (pitch 5.08)
LengthND
1- Exc. Load cell
2+ Exc. Load cell
3+ Load cell Sense
4- Load cell Sense
5- Signal load cell
6+ signal load cell
7- Analog output
8+ Analog output
9Input 1
10Input 2
11Input 3 (analog input option)
12Common input
13Output 1
14Output 2
15Output 3
16Output 4
17Common output
Type9 pin Sub-D
LengthND
1NC
2RS232 Rx
3RS232 Tx
4RS422 TX+
5GND
6RS422 TX-
7RS422 RX-
8RS232 CTS
9RS422 RX+
Connections  Indicator WIN11

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means