Cookie Consent by Free Privacy Policy website

Indicator WIN13


Download PDF

Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.

Indicator

Download installation manual

Download usage manual


Zoom Click to enlarge image

Indicator WIN13

Technical Specifications

Power supply230 / 115 V ac, 50 / 60 Hz – option 12 V dc
Max power consumption15 VA
IsolationClass II
Installation CategoryCategory II
Operating temperature-10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayNumeric 7-digit, 7-segment LED (h 14 mm)
Led7 3 mm indicator LEDs
Keyboard14 membrane buttons with buzzer
Overall dimensions144 x 72 x 120 mm / 5.67 x 2.83 x 4.72 in (l x h x p) (DIN43700)
MountingPanel mount
Case materialSelf-extinguishing Noryl (UL94 V1)
Protection levelIP 54
ConnectionsRemovable screw terminal blocks 5.08 pitch (power supply pitch7.5), serial ports on 9-pole SUB-D plug
Power supply load cells5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit
Input sensitivity≥ 0,02 μV
Linearity< 0.01% of full scale
Temperature deviation<0,0003% of full scale/°C
Internal resolution24 bit
Weight resolutionUp to 600.000 counts (6.000 if legal)
Measuring range-3.9 mV/V - +3.9 mV/V
Weight acquisition frequency6 Hz - 160 Hz
Digital filter0.2 Hz - 50 Hz
Output rate5 Hz - 50 Hz
Number of weight decimalsfrom 0 to 4 decimal digit
Zero / FS CalibrationAutomatic (theoretical) or executable through buttons
Analog output in tension0 – 10 V / 0 – 5 V
 Resolution16 bits
 CalibrationDigital through buttons
 Impedance≥ 10 kΩ
 Linearity0.03% full scale
 Temperature deviation0.001% full scale / °C
Analog output under current0 - 20 mA / 4 - 20 mA
 Resolution16 bits
 CalibrationDigital through buttons
 Impedance≤ 300 Ω
 Linearity0.03% full scale
 Temperature deviation0.001% of full scale/°C
Logical output6 relays (NO contact) maximum 115 V ac / 30 V dc, 0.5 A each
Logical input8 opto-isolated at 12 / 24 V direct current PNP
Additional logic outputs2 external boards of 8 relays as above (optional)
Serial portCOM1: Rs232c half duplex COM2: Rs422/Rs485 half duplex
 Max. cable length15m (Rs232c) and 1000m (Rs422 and Rs485)
 Serial protocolsASCII, Stampanti Alfapanel, EPSON, Modbus
 Baud rate1200, 2400, 4800, 9600, 19200, 38400, 115000 selectable
Program code memory128 Kbytes FLASH re-programmable on board via RS232
Data memory8 Kbytes expandible up to 36 Kbytes
Optional fiscal memory1 Mbytes (up to 160.000 weighing saved)
Calendar clockOn motherboard with buffer battery
Conforms to standardsEN61000-6-2, EN61000-6-3, EN61010-1, EN45501
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

Type9 pin Sub-D
LengthND
1NC
2RS232 Rx
3RS232 Tx
4RS422 TX+
5GND
6RS422 TX-
7RS422 RX-
8RS232 CTS
9RS422 RX+
TypeTerminal block 3P (pitch 7.5)
LengthND
1230V~ Line
2230V~ Neutral
3GND
TypeTerminal block 11P (pitch 5.08)
LengthND
1Output 1
2Output 2
3Common output
4Output 3
5Output 4
6Output 5
7Output 6
8Common output
9+12V Encoder
10Encoder Input
110 encoder
TypeTerminal block 15P (pitch 5.08)
LengthND
1- Exc. Load cell
2+ Exc. Load cell
3+ Load cell Sense
4- Load cell Sense
5- Signal load cell
6+ signal load cell
7Input 1
8Input 2
9Input 3
10Input 4
11Input 5
12Input 6
13Common input
14+ Analog output (input 7)
15- Analog output (Input 8)
Connections  Indicator WIN13

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means